Multi-site architecture
Two separate Digital Realty sites in the Paris area: PAR2 in Aubervilliers and PAR6 in Ivry-sur-Seine.
01 / Virtual machines
Size each VM according to your applications, your usage and your performance needs.
The resources of each VM can be adjusted month by month — up or down — as needs evolve: CPU, memory, storage and other associated resources.
Changes made during a month are reflected in the following month’s invoice (M+1).
Adjustable computing power
Memory sized to your needs
Suitable capacity and performance
Linux as standard
— Sizing tailored to each project.


02 / Infrastructure
Discover where the equipment is located and the principles of physical redundancy.
Two separate Digital Realty sites in the Paris area: PAR2 in Aubervilliers and PAR6 in Ivry-sur-Seine.
The infrastructure is designed with no single point of failure: redundant power supplies and network links, duplicated hypervisors and network equipment. Data is replicated across three nodes within the Ceph architecture.
Roles are separated across the sites: production, backup and disaster recovery, to limit the impact of a major incident or disaster at one site.
As part of a Disaster Recovery Plan (DRP), virtual machines are duplicated on the standby infrastructure and kept ready to be restarted so that production can resume in the event of a major disaster.

03 / Connectivity
Multi-carrier connectivity, combining peering and several transit providers to avoid any dependence on a single network.
Nine IX peering and several transit providers: Telia / Arelion, OpenTransit / Orange and Moji / Cogent.
Diversified links, carriers and network paths to keep connectivity running.
Pilot’s own IP block, independent of the carriers, announced through several multi-homed BGP routes to preserve flexibility and service continuity.

04 / High availability
Two levels of high availability can be implemented: automatic VM recovery if a hypervisor fails, or real-time failover for the most critical services.
With Proxmox, a hypervisor failure is detected automatically and the affected VMs can be restarted on another available node of the cluster.
VM data relies on a redundant Ceph architecture, replicated across several nodes. It remains available when a physical server goes down.
For critical architectures, services can be replicated across several VMs. Heartbeat and floating IP mechanisms automatically redirect traffic to an available instance in the event of a failure.